System Integration Guide

Preparing System for Integration

  • Download the ISO image here: <Link>
  • Install the NeuroICH Operating System
  • Connect Current Existing DICOM to NeuroCareAI DICOM
  • For Hospital DICOM server to NeuroICH DICOM server connection, Following details of hospital server will be required:
    • IP Address
    • Port
    • Username
    • Password
  • NeuroCareAI will allocate 30 mins to activate the system and help with basic questions of integration
  • If you need more help in integration we will charge 25 USD per hour for remote integration support. Two hours pre-paid are necessary to secure our service
  • NeuroCareAI will assist in activating Admin account and Site on our platform

Integration Testing

  • Our engineers will test integration on our side to confirm image transmission

WebView Access

  • Once testing is completed
  • After integration, you will be able to access imaging immediately at the following URL: Neuroview.APP from any workstation connected over the Local Area Network (LAN).

Add End-user Details

  • Site Admins can add end-user details access via this portal <>
  • Site Admin will be responsible to ensure end-user access
  • We recommend month review of all end-users to remove in-active end-users

Other FAQs

Indication for Use

NeuroICH is a notification-only, parallel workflow tool for use by hospital networks and trained clinicians to identify and communicate images of suspected ICH patients to a specialist, independent of standard of care workflow.

The device uses an artificial intelligence algorithm to analyze non-contrast CT images of the brain acquired in the acute setting for findings suggestive of intracranial hemorrhage (ICH) in parallel to the ongoing standard of care image interpretation and notify an appropriate clinician of these findings. Notifications include compressed non-diagnostic preview images that are meant for informational purposes only. The device does not alter or remove the original medical image and is not intended to be used as a diagnostic device. Images can be previewed through a mobile application.

Notified clinicians are responsible for viewing non-compressed images on a diagnostic viewer per the standard of care and engaging in appropriate patient evaluation in conjunction with other patient information before making care-related decisions. NeuroICH is limited to analysis of imaging data and should not be used in-lieu of full patient evaluation or relied upon to make or confirm diagnosis.

What if we do NOT have a Hospital DICOM Server

We recommend using Orthanc server to build your own Hospital DICOM server Click Here

What is NeuroCare Data Governance and Quality Assurance program?

Reminder as per above Service agreement signed. The following data will be properly added for each study to ensure continue un-interrupted service

Must have fields for DICOM Files:

Patients’ Details:

  • Patient Name: The name of the patient
  • Patient Sex: The gender of the patient
  • Date Of Birth: The patient’s date of birth

Exam Details:

  • Institution Name: The name of the institution where the study was conducted
  • Referring Physician Name: The name of the referring physician
  • Study Date: The date of the study
  • Study Time: The time of the study

Series Details:

  • Image Orientation Patient: The orientation of the images in the series
  • Manufacturer: The manufacturer of the imaging equipment
  • Modality: The imaging modality (e.g., CT scan)
  • Protocol Name: The name of the imaging protocol used
  • Series Date: The date when the series was created
  • Series Time: The time when the series was created
  • Series Description: A description of the series
  • Station Name: The name of the imaging station
  • Body Part Examined: The body part examined in the series

Instance Details:

  • Image Orientation Patient: The orientation of the image
  • Image Position Patient: The position of the image in relation to the patient
  • Type: The type of instance

Audit

  • A monthly audit needs be completed for above data governance program

What are the Minimum System Requirements for site Machine?

Please adhere to the following Minimum System Requirements:

Radiology Centers (<100 Scans/Month):

  • CPU: Intel Quad Core i5 Processor ( 3rd-5th Generation )
  • RAM: 16 GB DDR3
  • Hard Drive: 128 GB SSD + 512×2 GB Sata Drive.
  • Must Support Virtualization
  • Must have 2 Ethernet ports

Small Hospitals (100-1000 Scans/Month):

  • CPU: Atleast Intel i5 Quad Core Processor ( 5th-6th Generation )
  • RAM: 16 GB DDR3
  • Hard Drive: 128 GB SSD + TB SSD or Sata Drive
  • Must Support Virtualization
  • Must have 2 Ethernet ports

Large Hospitals (>1000 Scans/Month):

  • CPU: Intel i7 Quad core Processor (6th Generation or above)
  • RAM: 32 GB DDR4
  • Hard Drive: 256 GB SSD + 2×2 TB SSD or Sata Drive
  • Must Support Virtualization
  • Must have 2 Ethernet ports